Cause & Consequence
- Uncontrolled release of a flammable gas or liquid
Incident Location
Fixed Installation
Incident Activity
Production operations
Specific Incident Equipment
Oil export temperature probe
Lessons Identified
Operation of the export pumps had historically been continuous but had changed to stop/start operation in recent years due to reduced flowrate. It is important to consider the effects of operational change on all equipment associated with the change.
Incident Recommendations
Consider alternative measurement device eg surface mounted, to remove requirement for thermowell.
If thermowells are the only option, specify new thermowells with resistance to fatigue failure. New spec thermowells to take into account of operating envelope of pump and location of thermowell in relation to discharge of pump
Rate this alert
Average Rating
Latest Alerts & Moments
Our searchable catalogue of hundreds of Safety Alerts and Safety Moments are all designed as learning resources that can help improve workplace safety.