Alert
  • Published: 3 Apr 2025

Near miss: narrowly avoided fall from height due to missing deck gratings

Near miss narrowly avoided fall from height due to missing deck gratings
Near miss narrowly avoided fall from height due to missing deck gratings

Description of Incident

After a grating was removed, the Chief Engineer, on the way to inspect the work, nearly fell 4-5m.

During a docking, a grating was removed from a mezzanine level in the bow thruster space to allow lifting of machinery components from the bottom plates. Signs and barriers were installed at the bottom of the companionway leading up to the mezzanine, and around the missing section of deck itself. On completion of the lifting operation, the yard contractors removed the lifting equipment, along with the barriers around the hole. The barrier across the stairs remained in place, but the grating was not replaced at this time.

Subsequently, the Chief Engineer, on the way to inspect the work, entered the mezzanine level using a vertical access ladder directly from the forecastle, which had not been signed/barriered. At the bottom of the ladder he turned, took one step, and his next step was into the hole. He only managed to prevent a fall of 4-5m by instinctively reaching out to break his fall, ending up supported by his forearms and one leg, with the other hanging through the hole.

To view this safety alert published by IMCA in full, click the 'Download Alert' button above.

Rate this alert

Average Rating

Latest Alerts & Moments

Our searchable catalogue of hundreds of Safety Alerts and Safety Moments are all designed as learning resources that can help improve workplace safety.