What’s the difference? Safety Alerts give details of events surrounding an incident, near-miss or good practice. Safety Moments are downloadable PowerPoint presentations which give details of an incident, near-miss or good practice, discussion questions and related resources. Please note that every Safety Alert and Moment is deliberately kept anonymous to encourage sharing within the industry. No companies, installations, dates or names will be identified within the Alert or Moment.

Rate this Safety Alert
0
No votes yet
Hydrocarbon release from gas compression module During routine access to the gas compression module, a member of the platform team became aware of a hissing noise in the area of the 3rd Stage... Read more
31 Mar 2014
Rate this Safety Alert
0
No votes yet
Hydrocarbon release from atmospheric vent when blowing down annulus As part of TAR activities the closed drains were isolated for RV maintenance on the metering package. During the TAR, annulus blow... Read more
31 Mar 2014
Rate this Safety Alert
0
No votes yet
Unintended Hydrocarbon Release of Lube Oil resulting in fire in Pump Room At 0800hrs on 9th July the fire pump online was swapped from number 1 to number 3. The operator performed the necessary pre... Read more
31 Mar 2014
Rate this Safety Alert
0
No votes yet
Hydrocarbon Leak on MOL Pump Production was being reinstated on the installation following a planned five day outage. During the outage two flow control valves (FCVs) downstream of the ‘B’ Main Oil... Read more
31 Mar 2014
Rate this Safety Alert
0
No votes yet
Fire on Hedemora Diesel Engine Operations were planned to bring on Well WD P02 that would require the MOL pump and a standby diesel generator to be run. The CRO applied pre-authorised smoke detector... Read more
31 Mar 2014
Rate this Safety Alert
0
No votes yet
Hydrocarbon Leak from Prover Loop Sphere Door During nightshift, a Trainee Operator (TO) was performing his routine area readings and inspections; this included ‘G Module’ which houses the export... Read more
31 Mar 2014
Rate this Safety Alert
0
No votes yet
E-2510 Re-boiler channel head flange leak A technician picked up a smell of gas within a module. On investigation this was traced to the re-boiler channel head flange. The fixed gas detection showed... Read more
31 Mar 2014
Rate this Safety Alert
0
No votes yet
Hydrocarbon leak from 4 pipework Following production startup, a technician identified a small puddle of oil on the deck below the test separator. Oil was identified to be coming from a 4 " line... Read more
31 Mar 2014
Rate this Safety Alert
0
No votes yet
Diesel Spill from Gas separator day tank Whilst Operations were filling the Gas Compressor diesel tank a high diesel level alarm operated. The control room operator asked the technicians to check... Read more
31 Mar 2014
Rate this Safety Alert
0
No votes yet
Hydrocarbon release from a screwed drain valve connection on the underside of a 6 inch ball valve. A gas release occurred whilst carrying out blasting operations on a live line which was part of the... Read more
28 Mar 2014