What’s the difference? Safety Alerts give details of events surrounding an incident, near-miss or good practice. Safety Moments are downloadable PowerPoint presentations which give details of an incident, near-miss or good practice, discussion questions and related resources. Please note that every Safety Alert and Moment is deliberately kept anonymous to encourage sharing within the industry. No companies, installations, dates or names will be identified within the Alert or Moment.

Rate this Safety Alert
0
No votes yet
Gas leak from open 1/4" valve on gas turbine generator Whilst collecting daily readings in the main generator room an operations technician detected a slight smell of gas around the gas turbine. Upon... Read more
28 Mar 2014
Rate this Safety Alert
0
No votes yet
Controlled shutdown following reported smell of gas Assailers working in CD 16 reported smelling gas which, on investigation, was identified as coming from below the insulation on a 6" fuel gas... Read more
28 Mar 2014
Rate this Safety Alert
0
No votes yet
Gas leak from high pressure gas compressor recycle line An abseil technician reported a leak to the control room. An operations technician was then sent to check the source. The source was found to... Read more
28 Mar 2014
Rate this Safety Alert
0
No votes yet
Gas Release from Fuel Gas Skid drain Line Shortly after production was restarted, gas was smelt by a workparty who were working on the process deck in the vicinity of the fuel gas skid. It was... Read more
28 Mar 2014
Rate this Safety Alert
0
No votes yet
Minor gas leak from fitting in gas turbine hood As part of a site visit an operations technician entered the enclosure of the gas turbine and noticed a smell of gas. There were no alarms from the... Read more
28 Mar 2014
Rate this Safety Alert
0
No votes yet
Sight Glass Gas Leak A gas detector in a production module came in to low level alarm. Two Operations Technicians with gas meters were deployed to investigate. The technicians discovered a gas leak... Read more
28 Mar 2014
Rate this Safety Alert
0
No votes yet
Leak from oil export temperature probe During start up of oil export, area tech observed a leak from the temperature probe on the export pump discharge Read more
27 Mar 2014
Rate this Safety Alert
0
No votes yet
Gas release from level transmitter on HP Sep During a shutdown a level transmitter was removed to the workshop for overhaul. The device is flange mounted, however the head of the device was threaded... Read more
27 Mar 2014
Rate this Safety Alert
0
No votes yet
Gas leak during pigging operation During routine pigging operations, a temporary hose used for Nitrogen (N2) purging, ruptured on re-pressurisation with condensate of the Condensate Export pig... Read more
27 Mar 2014
Rate this Safety Alert
0
No votes yet
Gas turbine tripped due to an indication of gas inside the enclosure The gas turbine tripped due to an indication of gas inside the enclosure. The air inside the enclosure is monitored by three gas... Read more
27 Mar 2014